5YI5

human ferritin mutant - E-helix deletion


ELECTRON MICROSCOPY
Sample
human ferritin E-helix deletion mutant
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsblot for 9 seconds before plunging
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles429135
Reported Resolution (Å)3
Resolution MethodFSC 0.143 CUT-OFF
Other Detailsrelion2.0 program was used for the reconstruction
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (4Y08)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value29.56
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON II (4k x 4k)
Electron Dose (electrons/Å**2)2
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)
Maximum Defocus (nm)
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS0.002
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification47000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONRELION2.0
CTF CORRECTIONCTFFIND4.0
MODEL FITTINGUCSF Chimera1.10.2
INITIAL EULER ASSIGNMENTRELION2.0
FINAL EULER ASSIGNMENTRELION2.0
CLASSIFICATIONRELION2.0
RECONSTRUCTIONRELION2.0
MODEL REFINEMENTPHENIX1.10.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION623510