1IYY

NMR STRUCTURE OF Gln25-RIBONUCLEASE T1, 24 STRUCTURES


SOLUTION NMR
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAMX600
NMR Refinement
MethodDetailsSoftware
distance geometry and simulated annealingX-PLOR
NMR Ensemble Information
Conformer Selection Criteriastructures with the lowest energy
Conformers Calculated Total Number50
Conformers Submitted Total Number24
Additional NMR Experimental Information
DetailsStructures were refined by 1340 NOES (392 INTRARESIDUE, 384 SEQUENTIAL AND 564 LONG-RANGE NOES) using A DG/SA protocol. 37 assignments for 14 CHI-1 ANGLE, 21 PHI ANGLE AND 2 OMEGA ANGLE constraints were included during the course of the refinement.
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1refinementX-PLOR3.1
2structure solutionX-PLOR3.1