6TU3

Rat 20S proteasome


ELECTRON MICROSCOPY
Sample
Rat liver 20S proteasome
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Detailsblot for 3 seconds
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles245800
Reported Resolution (Å)2.7
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC2
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)37
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)1600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeDIFFRACTION
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsPreliminary grid screening was performed on Talos Arctica
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0
IMAGE ACQUISITIONEPU2.0
CTF CORRECTIONCTFFIND4
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.0
RECONSTRUCTIONRELION3.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION284161